LED Definitions
Port LED Definition for UfiSpace S9510-28DC
The network port LEDs are used to represent the status of the link associated with the LED.
| Port type | Condition | Status |
|---|---|---|
SFP+ |
Up |
Green |
Down |
Off |
|
SFP28 |
Up |
Green |
Down |
Off |
|
QSFP28 |
Up |
Green |
Down |
Off |
System LED Definition for UfiSpace S9510-28DC
The system LEDs are used to indicate the status of power and system.
| LED Indicators | Behavior | Status |
|---|---|---|
Power |
Off |
No power or in shut down mode. |
Solid Green |
System power is good. |
|
Blinking Green |
System power is good but BMC power is failed. |
|
Solid Yellow |
System power is good but CPU power is failed. |
|
Blinking Yellow |
System power failure. |
|
STAT (System Status) |
Off |
System (X86 and BMC) is not booted. |
Solid Green |
System boot is complete. |
|
Blinking Green |
System boot is in progress. |
|
Solid Yellow |
System boot is complete. (DIAG OS) |
|
Blinking Yellow |
Reserved |
|
PSU LED Functions and State |
Off |
No DC power to any of the PSUs. |
Flashing Red |
No DC power to this particular PSU. |
|
Flashing Green |
DC is present, only standby output is on. Poor contact. |
|
Green |
PSU output is on and normal. |
|
Red |
PSU failure. |
|
Flashing between Green and Red |
Warning. Working condition is not satisfied. Check the voltage, electric current, and temperature. |
|
FAN LED Functions and State |
Off |
Main board 3.3V power is failed or fan is not present. |
Solid Green |
Fan is present but interrupt assert |
|
Blinking Green |
NA |
|
Solid Yellow |
NA |
|
Blinking Yellow |
Fan is present but interrupt assert. |
Port LED Definition for Edgecore CSR440
The network port LEDs are used to represent the status of the link associated with the LED.
| Port type | Condition | Status |
|---|---|---|
10G |
Up |
Green |
Down |
LED is Off |
|
25G |
Up |
Blue |
Down |
LED is Off |
|
100G |
Up |
Two LEDs per port. Green (on QSFP28) and Violet (on QSFP-DD). |
Down |
LED is off |
System LED Definition for Edgecore CSR440
The system LEDs are used to indicate the status of power and system.
| Port type | Condition | Status |
|---|---|---|
PSU1 (power supply unit) |
Solid Green |
PSU1 is operating normally. |
Solid Amber |
Input power is present, but the PSU1 is not ON or is in a faulty state. |
|
Off |
The input power is not present or PSU1 is not present. |
|
PSU2 (power supply unit) |
Solid Green |
PSU2 is operating normally. |
Solid Amber |
Input power is present, but the PSU2 is not ON or is in a faulty state. |
|
Off |
Input power is not present or PSU2 is not present. |
|
DIAG (Diagnostic) |
Solid Green |
System self diagnostic test is successfully completed. |
Blinking Green |
System self-diagnostic test is in progress. |
|
Solid Orange |
System self-diagnostic test has detected a fault. |
|
FAN |
Solid Green |
All fan modules are present and working normally. |
Solid Orange |
Fan module is present but a fault has been detected. |
|
Off |
Fan module is not present. |
|
LOC |
Blinking Blue |
Flashing by remote management command. It helps technicians in finding the right device for service in the rack. It provides an indication of the location of the device. |
Off |
No indication. |
|
ALARM |
Solid Green |
No alarms detected. |
Solid Red |
Local alarm is detected. |
Port LED Definition for UfiSpace S9600-72XC
The network port LEDs are used to show the status of the link associated with the LED. In an UfiSpace S9600-72XC switch, there are 64*25G SFP28 ports and 8*100G QSFP28 on the front panel. SFP28 and QSFP28 operate in full duplex mode when the speed is 25Gbps and 100Gbps respectively.
| LED | Condition | Status |
|---|---|---|
SFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
|
QSFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
System LED Definition for UfiSpace S9600-72XC
The system LEDs are used to indicate the status of power and system.
| LED | Condition | Status |
|---|---|---|
SYS |
Off |
No power |
Solid Green |
Host CPU/BMC boot is complete |
|
Solid Amber |
Power is up, but host CPU/BMC boot is failed. |
|
FAN |
Off |
Fans are not initialized. |
Solid Green |
All fans are working normally. |
|
Blinking Amber |
Fan is not working. One or more fans need service. |
|
PSU1 |
Off |
No power |
Solid Green |
PSU1 is working normally. |
|
Blinking Amber |
PSU1 is failed. Service required. |
|
PSU2 |
Off |
No power |
Solid Green |
PSU2 is working normally. |
|
Blinking Amber |
PSU2 is failed. Service is needed. |
Port LED Definition for EdgeCore AGR420
The network port LEDs are used to represent the status of the link associated with the LED.
| Port type | Condition | Status |
|---|---|---|
SFP+ |
Up |
Blue LED is on (2 LEDs per port) |
Down |
Off |
|
SFP28 |
Up |
Blue LED is on (2 LEDs per port) |
Down |
Off |
|
QSFP28 |
Up |
Blue LED is on (2 LEDs per port) |
Down |
Off |
System LED Definition for Edgecore AGR420
The system LEDs are used to indicate the status of power and system.
| LED | Condition | Status |
|---|---|---|
DIAG (Diagnostic) |
Green |
System self diagnostic test is successfully completed. |
Amber |
System self-diagnostic test has detected a fault. (Faulty Fan, thermal, or any interface.) |
|
LOC |
Flashing Amber |
Flashing by remote management command. Assists technician in finding the right device for service in the rack. |
Off |
Not the switch that technician needs to find. |
|
FAN |
Green |
System fan is working normally. |
Amber |
Fan tray is present but system fan is faulty. |
|
Off |
System is off. |
|
PSU0 (power supply status) |
Green |
The power supply, #0, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
|
PSU1 (power supply status) |
Green |
The power supply, #1, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
Port LED Definition for UfiSpace S9600-32X
The network port LEDs are used to show the status of the link associated with the LED. In a UfiSpace S9600-32X switch, there are 4*10G SFP+ ports and 32*100G QSFP28 ports on the front panel. The SFP+ and QSFP28 ports operate in full duplex mode when the speed is 10Gbps and 100Gbps respectively.
| LED | Condition | Status |
|---|---|---|
SFP+ Port LED |
On (Green) |
Link is up |
Off |
No link |
|
QSFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
System LED Definition for UfiSpace S9600-32X
The system LEDs are used to indicate the status of power and system.
| LED | Condition | Status |
|---|---|---|
SYS |
Off |
System (x86 and BMC) is not booted. |
Solid Green |
System boot is complete. |
|
Blinking Green |
System boot is in progress. |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
Power is up but system boot is failed. |
|
Blinking Amber |
Reserved |
|
Fast Blinking Amber |
Reserved |
|
FAN |
Off |
Main board 3.3V_FAN power failure or no power. |
Solid Green |
All fans are working normally and interrupt de-assert. |
|
Blinking Green |
Fans PWMs do not match or each one fan no present |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
Each one of fans is failure (PWM=0) |
|
Blinking Amber |
Fan is present but interrupt assert. |
|
Fast Blinking Amber |
Reserved |
|
PSU1 |
Off |
No DC power or standby is failed. |
Solid Green |
PSU DC output is ON and standby is normal. |
|
Blinking Green |
No PSU is present. |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
PSU DC output is failed and standby is normal. |
|
Blinking Amber |
Warning. Working condition is not satisfied. (Check the voltage, electric current, and temperature). |
|
Fast Blinking Amber |
Reserved |
|
PSU2 |
Off |
No DC power or standby is failed. |
Solid Green |
PSU DC output is ON and standby is normal. |
|
Blinking Green |
No PSU is present. |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
PSU DC output is failed and standby is normal. |
|
Blinking Amber |
Warning. Working condition is not satisfied. (Check the voltage, electric current, and temperature). |
|
Fast Blinking Amber |
Reserved |
|
ID |
Off |
Turned off location of function |
Solid Blue |
Ready for location of function |
|
Blinking Blue |
Location of switch in telcom center |
|
Fast Blinking Blue |
Reserved. |
Port LED Definition for Edgecore AGR400
The network port LEDs are used to represent the status of the link associated with the LED.
| Port type | Condition | Status |
|---|---|---|
SFP28 |
Up |
Blue LED is on (Single LED per port) |
Down |
LED is Off |
|
QSFP28 |
Up |
Blue LED is on (2 LEDs per port) |
Down |
LED is Off |
|
QSFP-DD |
Up |
Not tested |
Down |
Not tested |
System LED Definition for Edgecore AGR400
The system LEDs are used to indicate the status of power and system.
| LED | Condition | Status |
|---|---|---|
DIAG (Diagnostic) |
Green |
System self diagnostic test is successfully completed. |
Amber |
System self-diagnostic test has detected a fault. (Faulty Fan, thermal, or any interface.) |
|
LOC |
Flashing Amber |
Flashing by remote management command. Assists the technician in finding the right device for service in the rack. |
Off |
Not the switch that the technician needs to find. |
|
FAN |
Green |
System fan is working normally. |
Amber |
Fan tray is present but system fan is faulty. |
|
Off |
System is off. |
|
PSU0 (power supply status) |
Green |
The power supply, #0, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
|
PSU1 (power supply status) |
Green |
The power supply, #1, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
Port LED Definition for UfiSpace S9610-46DX
The network port LEDs indicate the operational status of the associated interface. The UfiSpace S9610-46DX provides 40 QSFP28 (40/100G) ports, 6 QSFP-DD (100/200/400G) ports, and 4 SFP28/SFP-DD (1/10/25G) ports. All interfaces operate in full-duplex mode at their negotiated link speed.
| Port Type & Speed | LED State | Status |
|---|---|---|
SFP-DD 25G |
Green Solid |
Link up |
Blinking Green |
Packet transmitting or receiving |
|
Off |
No link or port disabled |
|
SFP-DD 10G/1G |
Amber Solid |
Link up |
Blinking Amber |
Packet transmitting or receiving |
|
Off |
No link or port disabled |
|
QSFP28 Non-breakout mode: 100G |
Green Solid |
Link up |
Blinking Green |
Packet transmitting or receiving |
|
Off |
No link or port disabled |
|
QSFP28 Non-breakout mode: 40G |
Amber Solid |
Link up |
Blinking Amber |
Packet transmitting or receiving |
|
Off |
No link or port disabled |
|
QSFP28 Breakout mode: 25G/port |
Green Solid |
All break-out ports link up |
Blinking Green |
All break-out ports have traffic activity |
|
Off |
All break-out ports link down |
|
Amber Solid |
Any one break-out port link down |
|
Blinking Amber |
Any break-out port has traffic activity |
|
Off |
All break-out ports link down |
|
QSFP-DD Non-breakout mode: 400G |
Green Solid |
Link up |
Blinking Green |
Packet transmitting or receiving |
|
Off |
No link or port disabled |
|
QSFP-DD Non-breakout mode: 100G |
Amber Solid |
Link up |
Blinking Amber |
Packet transmitting or receiving |
|
Off |
No link or port disabled |
|
QSFP-DD Breakout mode: 50G/port |
Solid Green |
All break-out ports link up |
Blinking Green |
All break-out ports have traffic activity |
|
Off |
All break-out ports link down |
|
Solid Amber |
Any one break-out port link down |
|
Blinking Amber |
Any break-out port has traffic activity |
|
Off |
All break-out ports link down |
System LED Definition for UfiSpace S9610-46DX
The system LEDs are used to indicate the status of power and system.
| LED | Condition | Status |
|---|---|---|
SYS |
OFF |
System (X86 & BMC) no boot |
Solid Green |
System boot complete (NOS) |
|
Blinking Green |
Reserved |
|
Solid Yellow |
Power is up but Host CPU/BMC boot failed |
|
Blinking Yellow |
Reserved |
|
FAN |
OFF |
Fans are not initialized |
Solid Green |
All FAN modules work well |
|
Blinking Green |
Reserved |
|
Solid Yellow |
Reserved |
|
Blinking Yellow |
One or more FAN module(s) fail or no FAN module present |
|
PS0 |
OFF |
No power |
Solid Green |
PSU0 is work normal |
|
Blinking Green |
Reserved |
|
Solid Yellow |
Reserved |
|
Blinking Yellow |
PSU0 fail (PSU0 need service) |
|
PS1 |
OFF |
No power |
Solid Green |
PSU1 is work normal |
|
Blinking Green |
Reserved |
|
Solid Yellow |
Reserved |
|
Blinking Yellow |
PSU1 fail (PSU1 need service) |
|
SYNC |
OFF |
System timing synchronization is disabled or in free-run mode. |
Solid Green |
System timing core is synchronized to PTP packet (phase) or one of external timing sources, frequency is also locked. |
|
Blinking Green |
System is synchronized to PTP packet (frequency) or one of external timing (frequency) sources. |
|
Solid Yellow |
System timing core is in acquiring state or holdover mode. |
|
Blinking Yellow |
System timing synchronization fail, or acquiring/hold over time out. |
|
ID |
OFF |
No power |
Solid Blue |
Reserved |
|
Blinking Blue |
Enable beacon feature |
Port LED Definition for UfiSpace S9500-22XST
The network port LEDs are used to show the status of the link associated with the LED. In a UfiSpace S9500-22XST switch, there are 12*10G SFP+ ports, 8*25G SFP28 ports, and 2*100G QSFP28 ports on the front panel. The SFP, SFP28, and QSFP28 ports operate in a full duplex mode when the speed is 10Gbps, 25Gbps, or 100Gbps.
| LED | Condition | Status |
|---|---|---|
SFP+ Port LED |
On (Green) |
Link is up |
Off |
No link |
|
SFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
|
QSFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
System LED Definition for UfiSpace S9500-22XST
The system LEDs are used to indicate the status of power and system.
| LED Indicators | Condition | Status |
|---|---|---|
Power |
Off |
No power or in shut down mode. |
Solid Green |
System power is good and the BMC heating is complete. |
|
Blinking Green |
System power is good and the BMC heating is in progress. |
|
Solid Yellow |
System power is good but BMC heating is failed. |
|
Blinking Yellow |
System power failure. |
|
STAT (System Status) |
Off |
System (X86 and BMC) is no booted. |
Solid Green |
System boot is complete. |
|
Blinking Green |
System boot is in progress. |
|
Solid Yellow |
Reserved |
|
Blinking Yellow |
Reserved |
|
PSU LED Functions and State |
Off |
No DC power to any of the PSUs. |
Flashing Red |
No DC power to this particular PSU. |
|
Flashing Green |
DC is present, only standby output is on. Poor contact. |
|
Green |
PSU DC output is on and is normal. |
|
Red |
PSU failure. |
|
Flashing between Green and Red |
Warning. Working condition is not satisfied. Check the voltage, electric current, and temperature. |
|
FAN LED Functions and State |
Off |
Main board 3.3V power is failed or fan is not present. |
Solid Green |
Fan is present and interrupt de-assert. |
|
Blinking Green |
NA |
|
Solid Yellow |
NA |
|
Blinking Yellow |
Fan is present but interrupt assert. |