LED Definitions
Port LED Definition for UfiSpace S9500-22XST
The network port LEDs are used to show the status of the link associated with the LED. In a UfiSpace S9500-22XST switch, there are 12*10G SFP+ ports, 8*25G SFP28 ports, and 2*100G QSFP28 ports on the front panel. The SFP, SFP28, and QSFP28 ports operate in a full duplex mode when the speed is 10Gbps, 25Gbps, or 100Gbps.
LED | Condition | Status |
---|---|---|
SFP+ Port LED |
On (Green) |
Link is up |
Off |
No link |
|
SFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
|
QSFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
System LED Definition for UfiSpace S9500-22XST
The system LEDs are used to indicate the status of power and system.
LED Indicators | Condition | Status |
---|---|---|
Power |
Off |
No power or in shut down mode. |
Solid Green |
System power is good and the BMC heating is complete. |
|
Blinking Green |
System power is good and the BMC heating is in progress. |
|
Solid Yellow |
System power is good but BMC heating is failed. |
|
Blinking Yellow |
System power failure. |
|
STAT (System Status) |
Off |
System (X86 and BMC) is no booted. |
Solid Green |
System boot is complete. |
|
Blinking Green |
System boot is in progress. |
|
Solid Yellow |
Reserved |
|
Blinking Yellow |
Reserved |
|
PSU LED Functions and State |
Off |
No DC power to any of the PSUs. |
Flashing Red |
No DC power to this particular PSU. |
|
Flashing Green |
DC is present, only standby output is on. Poor contact. |
|
Green |
PSU DC output is on and is normal. |
|
Red |
PSU failure. |
|
Flashing between Green and Red |
Warning. Working condition is not satisfied. Check the voltage, electric current, and temperature. |
|
FAN LED Functions and State |
Off |
Main board 3.3V power is failed or fan is not present. |
Solid Green |
Fan is present and interrupt de-assert. |
|
Blinking Green |
NA |
|
Solid Yellow |
NA |
|
Blinking Yellow |
Fan is present but interrupt assert. |
Port LED Definition for UfiSpace S9600-32X
The network port LEDs are used to show the status of the link associated with the LED. In a UfiSpace S9600-32X switch, there are 4*10G SFP+ ports and 32*100G QSFP28 ports on the front panel. The SFP+ and QSFP28 ports operate in full duplex mode when the speed is 10Gbps and 100Gbps respectively.
LED | Condition | Status |
---|---|---|
SFP+ Port LED |
On (Green) |
Link is up |
Off |
No link |
|
QSFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
System LED Definition for UfiSpace S9600-32X
The system LEDs are used to indicate the status of power and system.
LED | Condition | Status |
---|---|---|
SYS |
Off |
System (x86 and BMC) is not booted. |
Solid Green |
System boot is complete. |
|
Blinking Green |
System boot is in progress. |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
Power is up but system boot is failed. |
|
Blinking Amber |
Reserved |
|
Fast Blinking Amber |
Reserved |
|
FAN |
Off |
Main board 3.3V_FAN power failure or no power. |
Solid Green |
All fans are working normally and interrupt de-assert. |
|
Blinking Green |
Fans PWMs do not match or each one fan no present |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
Each one of fans is failure (PWM=0) |
|
Blinking Amber |
Fan is present but interrupt assert. |
|
Fast Blinking Amber |
Reserved |
|
PSU1 |
Off |
No DC power or standby is failed. |
Solid Green |
PSU DC output is ON and standby is normal. |
|
Blinking Green |
No PSU is present. |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
PSU DC output is failed and standby is normal. |
|
Blinking Amber |
Warning. Working condition is not satisfied. (Check the voltage, electric current, and temperature). |
|
Fast Blinking Amber |
Reserved |
|
PSU2 |
Off |
No DC power or standby is failed. |
Solid Green |
PSU DC output is ON and standby is normal. |
|
Blinking Green |
No PSU is present. |
|
Fast Blinking Green |
Reserved. |
|
Solid Amber |
PSU DC output is failed and standby is normal. |
|
Blinking Amber |
Warning. Working condition is not satisfied. (Check the voltage, electric current, and temperature). |
|
Fast Blinking Amber |
Reserved |
|
ID |
Off |
Turned off location of function |
Solid Blue |
Ready for location of function |
|
Blinking Blue |
Location of switch in telcom center |
|
Fast Blinking Blue |
Reserved. |
Port LED Definition for UfiSpace S9600-72XC
The network port LEDs are used to show the status of the link associated with the LED. In an UfiSpace S9600-72XC switch, there are 64*25G SFP28 ports and 8*100G QSFP28 on the front panel. SFP28 and QSFP28 operate in full duplex mode when the speed is 25Gbps and 100Gbps respectively.
LED | Condition | Status |
---|---|---|
SFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
|
QSFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
System LED Definition for UfiSpace S9600-72XC
The system LEDs are used to indicate the status of power and system.
LED | Condition | Status |
---|---|---|
SYS |
Off |
No power |
Solid Green |
Host CPU/BMC boot is complete |
|
Solid Amber |
Power is up, but host CPU/BMC boot is failed. |
|
FAN |
Off |
Fans are not initialized. |
Solid Green |
All fans are working normally. |
|
Blinking Amber |
Fan is not working. One or more fans need service. |
|
PSU1 |
Off |
No power |
Solid Green |
PSU1 is working normally. |
|
Blinking Amber |
PSU1 is failed. Service required. |
|
PSU2 |
Off |
No power |
Solid Green |
PSU2 is working normally. |
|
Blinking Amber |
PSU2 is failed. Service is needed. |
Port LED Definition for UfiSpace S9510-28DC
The network port LEDs are used to represent the status of the link associated with the LED.
Port type | Condition | Status |
---|---|---|
SFP+ |
Up |
Green |
Down |
Off |
|
SFP28 |
Up |
Green |
Down |
Off |
|
QSFP28 |
Up |
Green |
Down |
Off |
System LED Definition for UfiSpace S9510-28DC
The system LEDs are used to indicate the status of power and system.
LED Indicators | Behavior | Status |
---|---|---|
Power |
Off |
No power or in shut down mode. |
Solid Green |
System power is good. |
|
Blinking Green |
System power is good but BMC power is failed. |
|
Solid Yellow |
System power is good but CPU power is failed. |
|
Blinking Yellow |
System power failure. |
|
STAT (System Status) |
Off |
System (X86 and BMC) is not booted. |
Solid Green |
System boot is complete. |
|
Blinking Green |
System boot is in progress. |
|
Solid Yellow |
System boot is complete. (DIAG OS) |
|
Blinking Yellow |
Reserved |
|
PSU LED Functions and State |
Off |
No DC power to any of the PSUs. |
Flashing Red |
No DC power to this particular PSU. |
|
Flashing Green |
DC is present, only standby output is on. Poor contact. |
|
Green |
PSU output is on and normal. |
|
Red |
PSU failure. |
|
Flashing between Green and Red |
Warning. Working condition is not satisfied. Check the voltage, electric current, and temperature. |
|
FAN LED Functions and State |
Off |
Main board 3.3V power is failed or fan is not present. |
Solid Green |
Fan is present but interrupt assert |
|
Blinking Green |
NA |
|
Solid Yellow |
NA |
|
Blinking Yellow |
Fan is present but interrupt assert. |
Port LED Definition for EdgeCore AGR130
The network port LEDs are used to represent the status of the link associated with the LED. In an Accton/EdgeCore AGR130 switch, there are 48*10G SFP+ ports and 6*100G QSFP28 on the front panel, the all SFP/QSFP28 will operate in full duplex mode when the speed is 10Gbps or 100Gbps.
LED | Condition | Status |
---|---|---|
SFP+ Port LED |
On/Flashing Green |
Link at 10G, flashing indicates activity |
On/Flashing Amber |
Link at 1G, flashing indicates activity |
|
Off |
No link |
|
QSFP28 Port LED in 100G Mode (Port 49 - 54) |
On/Flashing Green |
Link at 100G, flashing indicates activity |
Off |
No link |
|
QSFP28 Port LED in 25G Breakout Mode |
On/Flashing Amber |
Link at 25G in breakout mode, flashing indicates activity |
Off |
No link |
|
QSFP28 Port LED in 40G Mode (Port 49 - 54) |
On/Flashing Blue |
Link at 40G mode, flashing indicates activity |
Off |
No link |
|
QSFP28 Port LED in 10G Breakout Mode |
On/Flashing Purple |
Link at 10G in breakout mode, flashing indicates activity |
Off |
No link |
System LED Definition for Edgecore AGR130
The system LEDs are used to indicate the status of power and system.
LED | Condition | Status |
---|---|---|
PSU1 (Power Supply Status) |
Green |
Power is operating normally |
Amber |
Power supply is present but not powered on or faulty. |
|
Off |
Power supply is not present. |
|
PSU2 (Power Supply Status) |
Green |
Power is operating normally |
Amber |
Power supply is present but not powered on or faulty. |
|
Off |
Power supply is not present. |
|
Diag (Diagnostic) |
Green |
System self-diagnostic test is successfully completed. |
Amber |
System self-diagnostic test detected a fault. |
|
FAN |
Green |
System FAN is operating normally |
Amber |
Fan tray is present buy system FAN is faulty. |
|
Off |
System is off |
Port LED Definition for EdgeCore AGR420
The network port LEDs are used to represent the status of the link associated with the LED.
Port type | Condition | Status |
---|---|---|
SFP+ |
Up |
Blue LED is on (2 LEDs per port) |
Down |
Off |
|
SFP28 |
Up |
Blue LED is on (2 LEDs per port) |
Down |
Off |
|
QSFP28 |
Up |
Blue LED is on (2 LEDs per port) |
Down |
Off |
System LED Definition for Edgecore AGR420
The system LEDs are used to indicate the status of power and system.
LED | Condition | Status |
---|---|---|
DIAG (Diagnostic) |
Green |
System self diagnostic test is successfully completed. |
Amber |
System self-diagnostic test has detected a fault. (Faulty Fan, thermal, or any interface.) |
|
LOC |
Flashing Amber |
Flashing by remote management command. Assists technician in finding the right device for service in the rack. |
Off |
Not the switch that technician needs to find. |
|
FAN |
Green |
System fan is working normally. |
Amber |
Fan tray is present but system fan is faulty. |
|
Off |
System is off. |
|
PSU0 (power supply status) |
Green |
The power supply, #0, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
|
PSU1 (power supply status) |
Green |
The power supply, #1, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
Port LED Definition for Edgecore AGR400
The network port LEDs are used to represent the status of the link associated with the LED.
Port type | Condition | Status |
---|---|---|
SFP28 |
Up |
Blue LED is on (Single LED per port) |
Down |
LED is Off |
|
QSFP28 |
Up |
Blue LED is on (2 LEDs per port) |
Down |
LED is Off |
|
QSFP-DD |
Up |
Not tested |
Down |
Not tested |
System LED Definition for Edgecore AGR400
The system LEDs are used to indicate the status of power and system.
LED | Condition | Status |
---|---|---|
DIAG (Diagnostic) |
Green |
System self diagnostic test is successfully completed. |
Amber |
System self-diagnostic test has detected a fault. (Faulty Fan, thermal, or any interface.) |
|
LOC |
Flashing Amber |
Flashing by remote management command. Assists the technician in finding the right device for service in the rack. |
Off |
Not the switch that the technician needs to find. |
|
FAN |
Green |
System fan is working normally. |
Amber |
Fan tray is present but system fan is faulty. |
|
Off |
System is off. |
|
PSU0 (power supply status) |
Green |
The power supply, #0, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
|
PSU1 (power supply status) |
Green |
The power supply, #1, is working normally. |
Amber |
Power is present, but not ON. Power is faulty. |
|
Off |
Power supply is not present. |
Port LED Definition for Edgecore CSR320
The network port LEDs are used to represent the status of the link associated with the LED.
Port type | Condition | Status |
---|---|---|
SFP+ |
Up |
Green LED is on |
Down |
LED is Off |
|
SFP28 |
Up |
Green LED is on |
Down |
LED is Off |
|
QSFP28 |
Up |
Green LED is on |
Down |
LED is off |
System LED Definition for Edgecore CSR320
The system LEDs are used to indicate the status of power and system.
Port type | Condition | Status |
---|---|---|
PSU0 (power supply status) |
Green |
The power supply, #0, is working normally. |
Amber |
Power is present, but not ON. Power supply is faulty. |
|
Off |
Power supply is not present. |
|
PSU1 (power supply status) |
Green |
The power supply, #1, is working normally. |
Amber |
Power is present, but not ON. Power supply is faulty. |
|
Off |
Power supply is not present. |
|
DIAG (Diagnostic) |
Green |
System self diagnostic test is successfully completed. |
Blinking Green |
System self-diagnostic test is in progress |
|
Amber |
System self-diagnostic test has detected a fault. |
|
FAN |
Green |
System fan is working normally. |
Blinking Green |
System FAN tray is powered off when ambient temperature is less than 10 degree C. |
|
Amber |
Fan tray is present but faulty. |
|
LOC |
Flashing Amber |
Flashing by remote management command. Assists the technician in finding the right device for service in the rack. |
Off |
Not the switch that the technician needs to find. |
Port LED Definition for Delta AGCVA48S
The network port LEDs are used to show the status of the link associated with the LED. In the Delta’s AGCVA48S switch, there are 4*10G SFP+ ports and 48*25G SFP28 ports, and 10*100G QSFP28 ports on the front panel. The SFP+, SFP28, and QSFP28 ports operate in full duplex mode even when the speed is 10Gbps, 25Gbps and 100Gbps respectively.
Port type | Condition | Status |
---|---|---|
SFP+ Port LED |
On (Green) |
Link is up |
Off |
No link |
|
SFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
|
QSFP28 Port LED |
On (Green) |
Link is up |
Off |
No link |
Port LED Definition for Edgecore CSR440
The network port LEDs are used to represent the status of the link associated with the LED.
Port type | Condition | Status |
---|---|---|
10G |
Up |
Green |
Down |
LED is Off |
|
25G |
Up |
Blue |
Down |
LED is Off |
|
100G |
Up |
Two LEDs per port. Green (on QSFP28) and Violet (on QSFP-DD). |
Down |
LED is off |
System LED Definition for Edgecore CSR440
The system LEDs are used to indicate the status of power and system.
Port type | Condition | Status |
---|---|---|
PSU1 (power supply unit) |
Solid Green |
PSU1 is operating normally. |
Solid Amber |
Input power is present, but the PSU1 is not ON or is in a faulty state. |
|
Off |
The input power is not present or PSU1 is not present. |
|
PSU2 (power supply unit) |
Solid Green |
PSU2 is operating normally. |
Solid Amber |
Input power is present, but the PSU2 is not ON or is in a faulty state. |
|
Off |
Input power is not present or PSU2 is not present. |
|
DIAG (Diagnostic) |
Solid Green |
System self diagnostic test is successfully completed. |
Blinking Green |
System self-diagnostic test is in progress. |
|
Solid Orange |
System self-diagnostic test has detected a fault. |
|
FAN |
Solid Green |
All fan modules are present and working normally. |
Solid Orange |
Fan module is present but a fault has been detected. |
|
Off |
Fan module is not present. |
|
LOC |
Blinking Blue |
Flashing by remote management command. It helps technicians in finding the right device for service in the rack. It provides an indication of the location of the device. |
Off |
No indication. |
|
ALARM |
Solid Green |
No alarms detected. |
Solid Red |
Local alarm is detected. |