RBFS Spine Image on Edgecore AGR400 (AS7946-30XB)

The RBFS Spine is a software image that supports aggregation functionality across the access leaves in a Spine Leaf deployment for BNG. This image is supported on Edgecore AGR400 (AS7946-30XB) platform.

Hardware Specification

Edgecore AGR400 Hardware Specification

Model

EdgeCore AGR400 (AS7946-30XB)

Form-factor

2RU, 19 Inch, Rack-Mountable

Switching Capacity

2.4 Tbps

Switch ASIC

Broadcom Qumran-2C BCM88823

Co-Processor

-

CPU

Intel Broadwell (8-Core)

Role

Spine

System Memory

SDRAM DDR4 SO-DIMM 32GB (16 GB x 2)

Storage (SSD)

128 GB

Interfaces

  • 26 x 100G

  • 4 x 25G

Max. Number of LAG Interfaces Supported Per LAG

33

Number of LAG Members Supported Per LAG

10

For more information, click the link below.
https://www.edge-core.com/solution-inquiry.php?cls=5&id=129

Port LED Definitions for 400G, 100G, 25G NIF Optical Transceivers on Edgecore AGR400 (AS7946-30XB)

The Edgecore AGR400 platform uses port LEDs to indicate link status, operational speed, and SerDes mode. The LED color reflects the active port configuration and is turned off when the link is down or any required SerDes lane is not operational.

The following table provides the LED status definitions for 400G, 100G, 25G NIF NIF ports associated with optical transceivers on the Edgecore AGR400 (AS7946-30XB) Spine device.

Port Type Number of Lanes / SerDes Rate (Gb/s) SerDes Mode LED1 (Speed/Link) Signaling LED2 (Activity) Signaling

400G QSFP-DD

8 / 53.125

PAM4

Solid Magenta (R+B). Off if one lane is not linked.

Solid Magenta (R+B), blink if activity. Off if one lane is not linked.

100G QSFP-DD

4 / 25.78125

NRZ

Solid Blue (B). Off if one lane is not linked.

Solid Blue (B), blink if activity. Off if one lane is not linked.

100G QSFP-DD

4 / 10.3125

NRZ

Solid Green (G). Off if one lane is not linked.

Solid Green (G), blink if activity. Off if one lane is not linked.

100G QSFP-28

4 / 25.78125

NRZ

Solid Blue (B). Off if one lane is not linked.

Solid Blue (B), blink if activity. Off if one lane is not linked.

100G QSFP28

4 / 10.3125

NRZ

Solid Green (G). Off if one lane is not linked.

Solid Green (G), blink if activity. Off if one lane is not linked.

25G SFP28

1 / 25.78125

NRZ

Solid Blue (B), blink if activity. Off if the lane is not linked.

Just have LED1

25G SFP28

1 / 10.3125

NRZ

Solid Green (G), blink if activity. Off if the lane is not linked.

Just have LED1

25G SFP28

1 / 1.25

NRZ

Solid Yellow (R+G), blink if activity. Off if the lane is not linked.

Just have LED1

Port LED Definitions for 400G/100G/25G Breakout Interfaces on Edgecore AGR400 (AS7946-30XB)

The following table provides the LED status definitions for 400G, 100G, 25G NIF breakout interfaces associated with optical transceivers on the Edgecore AGR400 (AS7946-30XB) Spine device.

Port Type Number of Breakout / SerDes Rate (Gb/s) SerDes Mode LED1 (Speed/Link) Signaling LED2 (Activity) Signaling

400G QSFP-DD

4 / 53.125 (4 × 100G)

PAM4

Solid Blue (B) if any lane is linked. Off if no lane is linked.

Solid Blue (B), blink if any lane is activity. Off if no lane is linked.

400G QSFP-DD

8 / 53.125 (8 × 50G)

PAM4

Solid Red ® if any lane is linked. Off if no lane is linked.

Solid Red ®, blink if any lane is activity. Off if no lane is linked.

400G QSFP-DD

8 / 25.78125 (8 × 25G)

NRZ

Solid Cyan (G+B) if any lane is linked. Off if no lane is linked.

Solid Cyan (G+B), blink if any lane is activity. Off if no lane is linked.

400G QSFP-DD (downgrade to 100G QSFP-DD)

2 / 25.78125 (2 × 50G)

NRZ

Solid Red ® if any lane is linked. Off if no lane is linked.

Solid Magenta Red ®, blink if any lane is activity. Off if no lane is linked.

400G QSFP-DD (downgrade to 100G QSFP-DD)

4 / 25.78125 (4 × 25G)

NRZ

Solid Cyan (G+B) if any lane is linked. Off if no lane is linked.

Solid Cyan (G+B), blink if any lane is activity. Off if no lane is linked.